Intrinsically Safe I/O Ex ib Obelix Modules
The Obelix Mining PLC I.S. I/O Modules provides intrinsically-safe (Group I Ex ib) input and output resources in a single, compact unit.
Solenoid I/O Generic (Type A) Exib Obelix Module
Part Number: LØLWØ1Ø1
Superseded Solenoid I/O (Type A) Exib Obelix Module
Part Number: LØLW51Ø1
Description Features Specifications Line Drawing Connector Assembly Fibre Optic Patch ST – ST Multi-Mode DescriptionA unique fibre-optic communications interface means that the module, and dedicated IS power supply, can be conveniently segregated into it’s own, isolated zone.
This solution is ideal for mobile mining equipment where limited installation space must be managed.
The fibre-optic link between the module and an Obelix processor module provides real-time control and monitoring of all I/O points.
FeaturesUniquely Keyed Type A connectors to prevent incorrect machine installation
- 24 x Solenoid-capable I.S. Outputs (12VDC / 300 mA Continuous rating)
- 24 x I.S. Digital Inputs (12 VDC)
- 16 x I.S. Analog Inputs (4 -20 mA)
- 16 x I.S. NAMUR-type Proximity Sensor Inputs
Module Type: Intrinsically Safe Input / Output
Supply Input: 12VDC (+/- 10%) / 20 Watts (Max) (Approved I.S. Supply)
Data Communications: Obelix Fibre
Operating Temperature: -20°C to 70°C
Inputs 1: 24 x I.S. Digital Inputs (12VDC)
Inputs 2: 16 x I.S. Analog Inputs (4-20 mA)
Inputs 3: 16 x I.S. Namur Inputs
Outputs: 24 x IS. 12VDC On/Off Outputs(300 mA Maximum each channel)
Connector 1: Obelix Fibre
Connector 2: Obelix A18(12VDC I.S. Supply Input and Solenoid Outputs) Connector 3: Obelix A19
(12VDC I.S. Supply Input and Namur Inputs) Connector 4: Obelix A20
(12VDC I.S. Digital Inputs and I.S. Analog Inputs) Line Drawing Connector Assembly
HØLWØ1Ø1 –
Connector Assembly A18 2.2 m
HØLWØ2Ø1 –
Connector Assembly A19 2.2 m
HØLWØ3Ø1 –
Connector Assembly A20 2.2 m
HØZFØ2Ø3 – A18 Cable Assembly
HØZFØ3Ø4 – A19 Cable Assembly
HØZFØ4Ø2 – A20 Cable Assembly
Fibre Optic Patch ST – ST Multi-ModeHØLWØ4Ø1 –
Fibre Optic Patch ST-ST Multi-mode