ObelixPLUS Mining PLC processor modules supports immediate integration into mobile mining machinery control and automation applications.

The products feature an unique dual-processor architecture – with one processor dedicated to fast, reliable I/O management and safety functions.

The second processor supports a flexible automation programming and configuration system.

Allowing end-users full access to high level control, automation and data collection.

Processor ObelixPLUS Module CODESYS (Standard)
Part Number: LØV411Ø1

LØV411Ø1

Description Description

In addition to sixteen (16) local digital inputs (24VDC); the module provides a number of field bus options – including CAN (4), Ethernet (2) and RS-422 (3).

The ObelixPLUS development environment – based on the popular CODESYS 3.5 programming tool chain – supports immediate integration of many industry-standard I/O devices and smart components.

Specification

Type: Programmable, dual-processor machine automation processor module

Programmability: CODESYS 3.5 PLC Development System

Local I/O: 16 x Digital Inputs (24 VDC)

Memory Battery: AS4871-compliant

LØV411Ø1 – Field Buses: 4 x CAN (copper) / 2 x Ethernet / 3 x RS-422

LØZU11Ø1 – Field Buses: 3 x CAN (copper) / 1 x CAN (fibre) with 8 ports / 2 x Ethernet / 3 x RS-422

Line Drawing

LØZU11Ø1

Description Description

In addition to sixteen (16) local digital inputs (24VDC); the module provides a number of field bus options – including CAN (4), Ethernet (2) and RS-422 (3).

Once of the CANbusses also features eight (8) fibre-optic ports for connection to intrinsically-safe I/O modules via fibre-optic cables.

The ObelixPLUS development environment – based on the popular CODESYS 3.5 programming tool chain – supports immediate integration of many industry-standard I/O devices and smart components.

Specification

Type: Programmable, dual-processor machine automation processor module

Programmability: CODESYS 3.5 PLC Development System

Local I/O : 16 x Digital Inputs (24 VDC)

Memory Battery: AS4871-compliant

LØV411Ø1 – Field Buses: 4 x CAN (copper) / 2 x Ethernet / 3 x RS-422

LØZU11Ø1 – Field Buses: 3 x CAN (copper) / 1 x CAN (fibre) with 8 ports / 2 x Ethernet / 3 x RS-422

Line Drawing Connector Assembly